I Have Made Five Different Solvent Blends, but I Cannot Tell Which One Performs Best — What Measurements Should I Record During a 30-Day Test?
Share
What do I record? Per bottle: gross weight with reeds in, every Monday, Wednesday and Friday (14 readings); a sealed check bottle each session; room temperature and humidity; clarity and colour; reed wetting on days 7, 14, 21, 30; and blind sniff scores on days 3, 7, 14, 21 and 30, one coded bottle at a time in a second room.
How do I pick the winner? Gates first, then rank: stable, inside your life window, still throwing on day 21, and three bottles that agree. Rank only the survivors, on day-21 throw, then cost.
What does CSI add? The identical parts: one oil lot (British Rose 500 gm ₹1,593.00 in the worked example), Gold 120 ML bottles, one lot of fibre reeds, and an optional control arm, Pure Performance 500 ML. The six-arm kit is ₹5,852.00. Your five solvent blends are yours: CSI sells no DPG, DPM, IPM or Augeo-type solvent.
- Straight answer: what to record
- Your five blends, restated
- Why five blends look alike: the cause table
- The 30-day measurement plan
- The data sheet, field by field
- Reading the numbers: an illustrative analysis
- Gate, then rank: choosing the winner
- What to buy for the test, and after it
- Frequently asked questions
Your five blends, restated
Your title gives the count, five, and the time, 30 days, but not the recipes, so this page uses a worked example you can map your own blends onto. Every blend carries the same oil at 20% by weight: 20 g of oil in 100 g, with 80 g of carrier. The carriers are your own solvents from your own supplier:
B1 DPG only (80 g DPG). B2 DPG 60 : DPM 40 (48 g DPG + 32 g DPM). B3 DPM 70 : DPG 30 (56 g DPM + 24 g DPG). B4 DPG 80 : IPM 20 (64 g DPG + 16 g IPM). B5 Augeo-type 50 : DPM 50 (40 g of a glycerol-ketal solvent + 40 g DPM). Augeo is a trademark of another company (Solvay); "Augeo-type" here means a solvent of that kind from your supplier.
The bottles: 120 ML Gold bottles, about 100 g in each, six Black fibre reeds (20.3 cm). The symptom: after a first run with one bottle per blend, all on one shelf in your workroom, two blends seemed "a bit stronger", the room smelled of rose whatever you did, and the bottles had lost weights you couldn't explain. That is a common starting point for a five-blend test, and it is fixable.
One real formula shows why. A CSI customer wrote in a review of Solar Bloom Fragrance Oil: "Fragrance is great but May be my formula for reed diffuser is 60% dpg 20% isopropyl myristate 10% perfume oil and 10% ethanol perfume grade. But throw of scent is low. Can you fix this formula." That is a four-part blend, DPG, IPM, ethanol and oil, and his question, which part to change, is the same as yours with five. The general tendencies are known: DPG is low in volatility, IPM is an oily, very slow ester, and DPM and ethanol are faster. But tendencies don't rank your five blends with your oil in your room. Only measurements do, and only if they are good enough to separate the blends from the noise. If you want to isolate which component of a two-part DPG and DPM blend is limiting, that is the cluster hub's component tests; this page is about measuring five finished blends well enough to pick one.
Why five blends look alike: the cause table
Before measuring more, list the reasons a test can fail to separate blends that really differ. Each of these rows adds noise. Your plan has to remove each one, or at least make it visible.
| Cause | What you'd see | Discriminating check | Fix |
|---|---|---|---|
| Solvent choice really is close: two blends differ by less than your bottle-to-bottle spread | Overlapping ranges in g/day and in sniff scores across the whole 30 days | Means differ by less than twice the larger arm's spread | Accept a tie; decide on cost, stability and supply |
| Fragrance load or oil character masks the carrier: a strong top-note oil smells "strong" in everything on day 3 | Early sniff scores all high; differences appear only from day 14 | Compare day-3 with day-21 scores; the fade, not the start, separates blends | Score through day 30; never decide on week one |
| Reeds, bottle, fill: different reed bundles, neck sizes or fill levels between arms | One bottle in an arm runs far from its two partners | Bottle spread above your limit; swap that bottle's reeds for fresh ones from the same lot | One reed lot dealt across arms; same bottle; weighed 100 g fills |
| Environment: sunny end of the shelf, a fan, AC cycling; and all 18 bottles scenting one room | Position predicts weight loss; every bottle "smells the same" in the room | Rotate positions each reading; sniff each coded bottle alone in a second room | Randomise the shelf; separate sniff room; log temperature and humidity |
| Measurement error: coarse scale, different times of day, reeds lifted out before weighing | Readings that zig-zag; a slow blend that seems to gain weight | A sealed check bottle weighed every session; repeat weighings of one bottle | Weigh the whole assembly, same hour, same scale, after the check bottle |
| Process: blends mixed on different days, unrested, from different solvent lots | An arm that differs from a repeat of itself | Make a duplicate master batch of the suspect arm and run it beside the first | One mixing day, written method, rest as you will in production; see the batch record guide |
| The nose: fatigue, expectation, one sniffer | Scores that rise for the blend the sniffer made "properly" | Blind codes; a repeat bottle hidden in the set | Two or three sniffers, codes, fixed order, fresh air between |
Two rows commonly cause most of the trouble. The first is one room for every bottle. Eighteen diffusers in a 10 m² room produce one combined smell, and nobody can attribute it. Throw has to be judged bottle by bottle, somewhere else. The second is scale resolution. A slow blend like B4 might lose about 0.30 g a day, so 0.60 g between two readings. On a scale that reads in 0.1 g steps, one step is 16.7% of that 2-day loss; on a 0.01 g scale it is 1.7%. Over the full 30 days (about 9 g) the same 0.1 g step is only 1.1%. So the rate you trust is the 30-day slope, not any single 2-day difference. A scale that reads in whole grams can't do this job at all.
The 30-day measurement plan
The plan has one rule: only the carrier changes. Six arms (your five blends plus an optional control arm that is not yours), three bottles each, 18 bottles in all. Everything else is identical and recorded. The method for diagnosing a single bottle that loses almost no weight, with open carrier-only controls, belongs to the controlled evaporation test; the general 30-day weight-loss method is in the live guide testing reed diffuser performance over 30 days. What follows is the five-arm version of both, with the record-keeping that makes the arms comparable.
Why weigh with the reeds in? Because lifting reeds out drips liquid back and loses some on your fingers, and both errors are bigger than a slow blend's daily loss. Weighing the whole assembly means the reeds' own uptake doesn't show as loss: liquid moving from bottle to reed stays on the scale. Only what leaves into the air registers. Weigh the reeds dry on day 0 and wet on day 30 if you want to know how much they hold.
Why a master batch per arm? Three separately mixed 100 g batches would add mixing error to the bottle-to-bottle spread. One 330 g master batch per arm, split into three 100.0 g fills plus a retain, means the three bottles differ only in bottle and reeds. That makes the spread a true measure of how repeatable the blend is in use. Record the batch exactly as the batch-record guide sets out: grams, lots, order, times.
Why sniff in a second room? Throw is what a person notices on entering a room. A small closed room, a 15-minute dwell, and a doorway sniff imitate that, one bottle at a time. Scores are 1 (barely there) to 5 (strong), plus "smells right" yes or no, because a blend that changes the oil's character (sharp, flat, solvent-like) has failed even if it is loud. Change the sniff order every session, so the same blend isn't always first. Nose fatigue is real; air the room and step outside between bottles.
The data sheet, field by field
Here is everything worth writing down. If it seems a lot, notice how many fields are filled once on day 0. On a normal reading you record a weight, a check weight, the room, a position and a clarity note: about two minutes for 18 bottles once you have a rhythm.
| Field | When | How / unit | Why it matters |
|---|---|---|---|
| Arm code, bottle code (e.g. B2-c) | setup | blind code on the base, key kept by someone else | stops expectation from scoring |
| Carrier recipe and lots | setup | grams of each solvent, supplier lot numbers | a winner you can't reproduce is no winner |
| Oil and lot; load | setup | g oil in g total, by weight | load must be identical across arms |
| Mixing order, time, rest | setup | e.g. carrier first, oil second, 2 min, 48 h rest | process changes clarity and early throw |
| Empty bottle + cap tare; reed dry weight | setup | g, two decimals if your scale has them | lets you separate liquid from reed uptake at the end |
| Fill weight | day 0 | g of liquid, target 100.0 g | per-bottle denominator for life |
| Gross weight (bottle + liquid + reeds) | every reading | g, same hour each day, before any flipping | the core measurement: loss = evaporation |
| Check-bottle weight | every reading | sealed spare bottle, g | scale drift detector |
| Room temperature and humidity; shelf position | every reading | °C, % RH (your own hygrometer), position number | explains jumps; feeds the rotation |
| Clarity, layers, sediment, colour | every reading | clear / haze / layers / sediment; phone photo on a white card | stability is a gate, not a score |
| Reed condition | days 7, 14, 21, 30 | how far up the reed the liquid darkens it (cm); sticky or dry tips | early warning of slowing or blockage |
| Blind sniff: intensity 1–5, "smells right" yes/no | days 3, 7, 14, 21, 30 | coded bottle alone in a second room, fixed distance and dwell | throw over time, not just on day 3 |
| Flip log | when you flip | date, time, after weighing | flips cause steps in the curve; all bottles flip together |
| End of test: liquid left, reed weight wet | day 30 | g | checks the arithmetic and reed uptake |
A worked example of the core number. Bottle B2-a weighs 352.40 g gross on day 0 and 317.90 g on day 30: it lost 34.50 g, so 1.15 g/day. At that rate a 100 g fill lasts about 87 days. Do the same for its two partners, take the mean, and the spread is (highest − lowest) ÷ mean. Also compute the rate for days 0–7 and days 7–30 separately. A blend that loses much faster early and then slows is shedding light materials first, which is often the "fresh notes vanish" pattern in the fresh-notes guide and the subject of differential evaporation. A blend whose rate drops sharply after week two, with dry-looking reed tips, may be blocking the reeds: the reed-blockage test covers that.
Reading the numbers: an illustrative analysis
Here is what a finished data set might look like for the five worked-example blends. These numbers are invented to show the method. They follow the general tendencies (DPG slow, IPM slower, DPM faster), but your oil, room and solvents may produce a different order, and the control arm is left blank because only your test can fill it.
| Blend | g/day (3 bottles) | Mean · spread | Life | Sniff day 7 / 21 | Stability | Gates |
|---|---|---|---|---|---|---|
|
B1 DPG only 80 g DPG |
0.44 / 0.45 / 0.46 | 0.45 · 4.4% | 222 days | 2 / 2 | clear | fails life (too slow) and throw |
|
B2 DPG 60 : DPM 40 48 g DPG + 32 g DPM |
1.12 / 1.15 / 1.18 | 1.15 · 5.2% | 87 days | 4 / 3 | clear | passes all four |
|
B3 DPM 70 : DPG 30 56 g DPM + 24 g DPG |
1.74 / 1.80 / 1.86 | 1.80 · 6.7% | 56 days | 4 / 2 | clear | fails life (too fast); fades by day 21 |
|
B4 DPG 80 : IPM 20 64 g DPG + 16 g IPM |
0.29 / 0.30 / 0.31 | 0.30 · 6.7% | 333 days | 1 / 1 | faint haze in the sealed retain, day 21 | fails throw and stability |
|
B5 Augeo-type 50 : DPM 50 40 g Augeo-type + 40 g DPM |
1.15 / 1.37 / 1.59 | 1.37 · 32.1% | 73 days | 4 / 3 | clear | fails consistency: re-run |
B3 is the trap. It is the fastest, at 1.80 g/day, and on day 7 it scored as high as anything. But a 100 g fill would last only about 56 days, outside the 60–90-day window, and by day 21 its median fell to 2. Speed bought early impact, not lasting throw. B1 and B4 are the opposite: stable, slow, long-lived and weak. Their curves sit far below the wedge. That is the classic DPG-heavy picture, and IPM made it slower still. B5 sits inside the window with good scores, but its three bottles ran at 1.15, 1.37, 1.59 g/day, a 32.1% spread. That says nothing yet about the blend; it says the arm is not repeatable as tested. Re-run it with a fresh master batch before you judge it: a mixing error, a bad reed bundle or a position effect is more likely than a blend that genuinely behaves three ways.
B2 passes all four gates: clear, 1.15 g/day (about 87 days for 100 g), day-21 median 3, spread 5.2%. On this data it is the winner. It wins because it is the one blend inside every limit, not because it is "best" on any single number. If the B5 re-run also passes, you have two survivors, and the ranking rule takes over.
When is a difference real?
With three bottles per arm, use a plain rule rather than statistics you can't check. Two arms differ in rate if their bottle ranges don't overlap. Two arms differ in throw if their medians differ by at least one point on two sessions out of the last three (days 14, 21, 30). Anything less is a tie. A tie is a result, not a failure: it means either blend will do, and you choose on cost per bottle, stability margin and how reliably you can buy the solvents. If a tie matters commercially, run the two finalists again with five bottles each. Choosing among three stable formulas for production takes that step further.
Watch the room log too. If every bottle's rate jumped in the same week, look at the temperature column before you look at the blends. A warm week speeds everything; it does not reorder the blends unless one is much more temperature-sensitive than the rest. That is worth knowing if you sell into Indian summers (roughly April to June). Rotation of shelf positions is what lets you say "the room changed" rather than "bottle 4 was by the window".
Gate, then rank: choosing the winner
Why not one weighted score out of 100? Because a single score lets a big number in one column hide a failure in another: a blend can "score 78" while separating on a cool shelf. Gates make failures final. Write them before day 0 so the data can't talk you into moving them.
| Gate | Example threshold (yours to set) | Measured from | If it fails |
|---|---|---|---|
| 1 · Stability | clear, no layer or sediment in bottles and in the sealed retain, all 30 days | visual log + photos | out, whatever the throw |
| 2 · Life | mean inside 1.11–1.67 g/day for a 100 g fill (60–90 days) | gross weights | out, or move to a different fill/reed count and re-test |
| 3 · Throw | median ≥ 3 on day 21, and no more than 1 point below its own day-7 score | blind sniffs | out |
| 4 · Consistency | bottle spread ≤ 15% of the arm mean | the three bottles | re-run the arm before judging |
| Rank survivors | day-21 throw first, then cost per bottle, then supply risk | sniffs, invoices, your supplier | — |
The life window is yours to set, from what you promise. If your label says "lasts up to 8 weeks", your window is built round 56 days, not this page's 60–90. Fill and reed count shift the rate too. If the winner runs slightly fast, the next test is that blend with five reeds instead of six, not a new blend. Cost per bottle comes after the gates. In the CSI arm of this kit the materials are ₹393.76 a bottle: oil ₹63.72, base ₹175.84 at a labelled 1.00 g/ml, bottle ₹106.20, reeds ₹48.00. For your own blends, add your carrier's cost per 80 g to ₹217.92. Excludes labour, freight, packaging and GST.
After a winner, two checks before production. First, repeat it: one more master batch, made on a different day, three bottles, 14 days. If it matches the first run's rate and day-14 score within your margin, the result is real. Second, extend the stability watch on the sealed retain. A 30-day performance test is not a shelf-life test; longer-term stability testing covers that. If you are deciding whether a home-made base is worth owning at all, compared with buying, the full development guide sets out the whole path.
What to buy for the test, and after it
Chosen on page statements, price and stock on 7 October 2026, not on performance: CSI publishes no diffusion data for any product. Each card is either the shared, identical part of every arm, or the optional control arm.
| Size | Price | Per gram | 100 g bottles at 20% | In this test |
|---|---|---|---|---|
| 15 gm | ₹94.40 | ₹6.29 | 0 | smell check only |
| 50 gm | ₹212.40 | ₹4.25 | 2 | one arm (66 g) won't fit |
| 100 gm | ₹342.20 | ₹3.42 | 5 | four cover 396 g with almost nothing spare |
| 500 gm | ₹1,593.00 | ₹3.19 | 25 | the six-arm test: 396 g used, 104 g left for a re-run |
| 1 kg | ₹3,068.00 | ₹3.07 | 50 | production, after a winner |
| Size | Price | Unit price | In this test |
|---|---|---|---|
| 100g | ₹325.00 | ₹3.25 a gram | too small for three bottles |
| 500 ML | ₹1,099.00 | ₹2.20 a ml | control arm: 264 g used (labelled 1.00 g/ml) |
| Size | Price | Per bottle | In this test |
|---|---|---|---|
| 50 ML Pack of 10 | ₹826.00 | ₹82.60 | too small for 100 g fills |
| 120 ML Pack of 10 | ₹1,062.00 | ₹106.20 | two packs: 18 test bottles + 2 spare |
| Pack | Price | Per reed | In this test |
|---|---|---|---|
| Pack of 25 | ₹236.00 | ₹9.44 | top-up |
| Pack of 50 | ₹400.00 | ₹8.00 | |
| Pack of 100 | ₹800.00 | ₹8.00 | 100 + 25 = 125 for 108 (17 spare) |
| Pack of 500 | ₹4,000.00 | ₹8.00 | production only, and only if you will use them |
| Item | Price | Use |
|---|---|---|
| Candle Making Weighing Scale | ₹354.00 | formulating; weighing only if your check shows 0.1 g or better |
After the test: 50 bottles of the winner. At 20 g of oil a bottle plus a 5% loss allowance (a worked-example figure) you need 1,050 g: the 1 kg and a 50 gm, ₹3,280.40. Bottles: five packs of 120 ML, ₹5,310.00. Reeds: 300 at six a bottle, three packs of 100, ₹2,400.00. A 500-pack would tie up ₹1,600.00 more for no saving per reed. If your own blend won, that is the whole CSI order, ₹10,990.40, and your carrier comes from your solvent supplier. If the Pure Performance arm won, add 4,200 ml of base, 9 packs of 500 ML at a labelled 1.00 g/ml, ₹9,891.00, for ₹20,881.40 in all. CSI lists no bulk tier for bases; ask on WhatsApp before planning around list price. Changing oil, reed lot or bottle after the test is a new test.
Skip: the CSI HyperDiffusion Base (out of stock on 7 October 2026), any 1 kg of oil before the repeat run, and the Isopropyl Alcohol Spray: it is a cleaner, not a diffuser ingredient. If your five blends include an ethanol arm, that alcohol comes from your own supplier, along with its safety data. For a three-ratio design around one jasmine oil, see the three-ratio experiment; to check whether a faster ratio really improved throw, the DPG-to-DPM ratio guide.
CandleMakingSuppliesIndia sells reed diffuser bases, fibre reeds, bottles and fragrance oils. It does not sell DPG, DPM, IPM, Augeo-type solvents or perfumer's alcohol. This page still tells you the control arm is optional, that your own blend may beat our base, that a 500-reed pack saves nothing per reed, and that our base pages publish no composition, density, flash point or SDS in the text we captured.
Every CSI price was checked on the live store on 7 October 2026, with stock checked per size. Every product and size offered here was in stock on that date; the CSI HyperDiffusion Base is out of stock and not offered. Page wording is quoted and attributed.
The five recipes, all performance figures, sniff scores, gates, the 60–90-day window and the 15% spread limit are labelled worked examples and judgement, not CSI test data. For bulk pricing, GST invoicing, and MSDS and IFRA documentation for our fragrance oils on request, message us on WhatsApp at +91 7397976926.
Frequently asked questions
- I Mixed DPG and DPM to Make My Own Reed Diffuser Base, but the Finished Diffuser Still Has Weak Throw — How Do I Determine Which Component Is Limiting Performance?
- I Want to Make My Own Reed Diffuser Base Instead of Buying a Ready-Made One — What Small-Batch Compatibility and Performance Tests Should I Complete First?
- I Changed My DPG-to-DPM Ratio, and the Diffuser Started Evaporating Faster — How Do I Check Whether Fragrance Throw Improved as Well?
- I Want to Test Three Carrier Ratios with One Jasmine Fragrance — How Do I Design the Experiment So Fragrance Percentage and Reed Count Remain Identical?
- I Mixed Two Solvents That Appear Compatible, but My Reed Diffuser Separates After a Week — What Longer-Term Stability Tests Should I Perform?
- I Made a Custom Reed Diffuser Base That Smells Strong Initially but Loses Its Fresh Notes Quickly — Could the Carrier Blend Be Changing the Evaporation Profile?
- I Want to Make a 1 Kg Reed Diffuser Base Trial from Multiple Solvents — How Do I Record Exact Ingredient Weights and Maintain Batch Traceability?
- I Want to Replace a Proprietary Ready-Made Base with My Own Solvent Blend — How Do I Compare Performance Without Assuming Similar Appearance Means Equivalent Quality?
- How Do I Develop My Own Reed Diffuser Base from Compatible Solvents, Test It with Several Fragrances, Measure Diffusion and Stability, and Decide Whether It Is Better Than Buying a Ready-Made Base?
Customer reviews: The six reviews at the top of this page are genuine, published Judge.me reviews left by CSI customers on the product pages named on each card — British Rose Fragrance Oil, Gold Reed Diffuser Bottle Pack of 10 (50 ML and 120 ML), Lift Base – Professional Grade Reed & Car Diffuser Base (500 ml), Solar Bloom Fragrance Oil. They are general product reviews, not assessments of the reed-diffuser formulation advice on this page. Names, star ratings, dates and products are as recorded by Judge.me and wording is unedited. "Verified buyer" appears only on reviews Judge.me recorded as verified — Pradeep Kumar Dahiya, Arshad Shaikh, snehal Chaudhary, Sooraj R. The reviews from Emma Bechara, Ashwini are published but not recorded as verified, and carry no badge.
Figures verified 7 October 2026, CSI live pricing: British Rose Fragrance Oil 15 gm ₹94.40, 50 gm ₹212.40, 100 gm ₹342.20, 500 gm ₹1,593.00 (₹3.19 a gram), 1 kg ₹3,068.00; Pure Performance Reed Base Oil 100g ₹325.00, 500 ML ₹1,099.00 (₹2.20 a ml); Gold Reed Diffuser Bottle 50 ML pack of 10 ₹826.00, 120 ML pack of 10 ₹1,062.00 (₹106.20 each); Fiber Diffuser Reeds (Black) 25 ₹236.00, 50 ₹400.00, 100 ₹800.00, 500 ₹4,000.00; Candle Making Weighing Scale ₹354.00. All in stock on 7 October 2026; the CSI HyperDiffusion Base is out of stock. Per gram, per ml and per item = price ÷ units, two decimals.
Non-price figures: the five carrier recipes, the 20% load, all g/day figures, sniff scores, stability notes, the 60–90-day life window, the 15% spread limit, the 5% production allowance and the 50-bottle run are labelled worked examples; the reader's title gives only "five blends" and "30 days". Three bottles per arm, 100 g fills, six 20.3 cm fibre reeds, a Monday/Wednesday/Friday weighing rhythm and sniff days 3, 7, 14, 21 and 30 are the series method; the sniff protocol is an in-house method, not a standard. Base cost per bottle uses a labelled 1.00 g/ml; CSI base pages state no density. Diwali 8 November 2026 and Christmas 25 December 2026 are calendar facts. Costs are materials only and exclude labour, freight, packaging and GST.